Lay Summary Auditor
A structured evaluation framework for detecting clinically meaningful errors in AI-generated lay summaries of medical evidence.
Source-blinded auditing against structured reference evidence, using an error taxonomy prespecified for the evaluation panel.
Extract published study findings into a field-traceable evidence table.
The generator and auditor share this table. Extraction errors can propagate through both stages without being detected by this pipeline. Source-to-table verification requires a separate check.
17 failure modes prespecified for the evaluation panel · Taxonomy v0.4
Developed iteratively through guidance review and initial case annotation.
COMMISSION · VERIFIABLE CLAIM
OMISSION · REQUIRED ELEMENT
States or implies a benefit that the evidence table does not support.
Presents a result as reliable, confirmed or significant when the analysis plan or reported values do not support it.
Prints confidence intervals, p values or test statistics numerically instead of explaining uncertainty in plain language, even when the values are correct.
Makes a quantitative statement that contradicts the evidence table: an incorrect value, denominator, direction or arithmetic derivation.
Reports a point estimate, difference, ratio or per-arm value for an outcome outside the confirmatory testing sequence, whether or not it is qualified.
Presents adverse event frequency as a bare percentage, or a percentage table without a denominator stated in words at the point of use, leaving a calculation to the reader.
Fails to convey that a non-significant or non-confirmatory result is unreliable or unconfirmed. For outcomes outside the testing sequence, the required qualification covers where full results are recorded, why testing was blocked and why benefit cannot be concluded.
Omits required trial identifiers, such as the title, protocol number or EU trial number.
Omits the sponsor's name or contact details.
Omits where or when the trial was conducted, its main objectives or the reasons for conducting it.
Omits participant numbers, age or gender breakdowns, or inclusion and exclusion criteria.
Omits information identifying the investigational medicinal products.
Omits adverse reactions or their frequency. If the source contains only a prespecified subset, that limitation must be stated.
Omits the trial's overall results.
Omits comments on the trial outcome.
Omits an indication of whether follow-up trials are foreseen.
Omits where readers can find additional information.
The taxonomy is a project-defined interpretation of the sources below, not an official classification of any regulatory authority. Omission codes are scored against the generator only where the evidence table carries the required information. Extraction gaps are recorded separately.
Sources and versions fixed in the protocol
- Regulation (EU) 536/2014, Annex V.
- CTR Questions & Answers, July 2026, chapter 6 (§6.1 and §6.2).
- Summaries of Clinical Trial Results for Laypersons, Expert Group on Clinical Trials, version 2, February 2018.
- Good Lay Summary Practice, version 1, October 2021: §3.4 and §3.3.6 (statistical terminology); §3.3.8 (quality control); §2.2.1 and §2.2.2 (outcome selection).
Built
- Generator and source-blinded auditor implemented.
- Four published trials extracted — PARAGON-HF, SELECT, RA-BEACON and a vortioxetine trial — with field-level traceability to source articles, tables and sections, covering three distinct mechanisms of hierarchical testing restrictions.
- Taxonomy v0.4 and documented annotation rules.
- Evaluation protocol and development observations.
Next
- Complete and freeze the human-annotated reference standard.
- Extend auditor coverage from 6 to 17 codes, then verify alignment and freeze the configuration.
- Execute the final evaluation panel.
- Measure sensitivity, specificity and run-to-run stability.
Supported auditor codes: C1–C5 and O1. Development observations documented. Final performance metrics not yet available.
RECORDED DEVELOPMENT CASE / CASE-003
A reversed claim. A recorded detection.
Synthetic development case with one deliberately injected direction error. Excluded from final evaluation metrics.
22.4% Synthemide 9.1% Placebo
Nausea reported in each group.
Source trace
Field: adverse_events[0].
The evidence-table file is inferred from the base
case's source:
examples/evidence-table-inference.json
.
The manifest records the field and values, but does
not name the file.
“Nausea was reported more often in people taking synthemide than in those taking placebo.”
“Nausea was reported more often in people taking placebo than in those taking synthemide.”
C4 · NUMERIC ERROR “The table shows nausea was more common in the synthemide group (22.4%) than placebo (9.1%), but the summary reverses this direction.”
View stored finding · JSON
{
"findings": [
{
"code": "C4",
"quote": "Nausea was reported more often in people taking placebo than in those taking synthemide.",
"table_reference": "adverse_events: nausea (intervention_pct 22.4, placebo_pct 9.1)",
"explanation": "The table shows nausea was more common in the synthemide group (22.4%) than placebo (9.1%), but the summary reverses this direction."
}
]
}
Provenance and limitations
Stored output:
evidence/development/audit-case-003.json
.
Base text:
cases/case-001.md
.
Altered text:
cases/case-003.md
.
The altered summary also contains the correct nausea values in its own table. Detection therefore does not isolate comparison against the external evidence table: internal inconsistency provides another possible cue.
Prompt version and execution metadata were not recorded in the stored output and cannot be recovered reliably. This single development case does not establish auditor performance. The final evaluation panel has not been executed.
02 / COMMUNICATION
Evidence, made understandable.
FEATURED / EVIDENCE BRIEF
Obesity Explained
A plain-language introduction to obesity, treatment options and ongoing care.
Read the evidence brief ↗FROM EVIDENCE TO UNDERSTANDING
- 01 Understanding obesity
- 02 Comparing treatment options
- 03 Benefits, risks & uncertainty
- 04 Sources you can follow
Plain language · Scientific & regulatory references
PLAIN-LANGUAGE SUMMARY
EMERGENT-3 / KarXT
An independent writing sample explaining a schizophrenia trial, its findings and limitations for a non-specialist audience.
Read the summary ↗PATIENT EDUCATION
Understanding High Blood Pressure
A practical guide to blood pressure readings, everyday habits and when to seek help.
Read the guide ↗MEDICAL PUBLICATION
Myxoinflammatory Fibroblastic Sarcoma
Co-authored case report published in 2015.
Read the publication ↗03 / BACKGROUND
Built in clinical practice.
Clinical practice & documentation
Ten years across primary care, occupational health and emergency medicine in Brazil. Experience producing structured medical reports with traceable reasoning for external and medico-legal review.
Education & current work
Medical degree from Faculdade de Medicina de Itajubá. Postgraduate training in Artificial Intelligence and Data Science in Healthcare at Hospital Sírio-Libanês in progress.
Currently developing an independent evaluation framework for AI-generated lay summaries. Native Brazilian Portuguese; professional working proficiency in English.
04 / CONTACT
Let’s talk about clinical AI quality.
Open to opportunities and collaborations in healthcare AI evaluation, clinical content review and medical writing.